Setting Conditions
Table of Equivalent Factors
Table4 Equivalent Factors of Model LM
Model No. | Equivalent factor: K | |
---|---|---|
Single nut | Double blocks | |
LM 3 | 1.566 | 0.26 |
LM 4 | 1.566 | 0.21 |
LM 5 | 1.253 | 0.178 |
LM 6 | 0.553 | 0.162 |
LM 8S | 0.708 | 0.166 |
LM 8 | 0.442 | 0.128 |
LM 10 | 0.389 | 0.101 |
LM 12 | 0.389 | 0.097 |
LM 13 | 0.343 | 0.093 |
LM 16 | 0.279 | 0.084 |
LM 20 | 0.257 | 0.071 |
LM 25 | 0.163 | 0.054 |
LM 30 | 0.153 | 0.049 |
LM 35 | 0.143 | 0.045 |
LM 38 | 0.127 | 0.042 |
LM 40 | 0.117 | 0.04 |
LM 50 | 0.096 | 0.032 |
LM 60 | 0.093 | 0.028 |
LM 80 | 0.077 | 0.022 |
LM 100 | 0.065 | 0.017 |
LM 120 | 0.051 | 0.015 |
Note) Equivalent factors for the following models are the same as for model LM: Models LMF, LMK, LMIF, LMIK, LMIH, LMH, and SC.
Table5 Equivalent Factors of Model LM-L
Model No. | Equivalent factor: K |
---|---|
Single nut | |
LM 3L | 0.654 |
LM 4L | 0.578 |
LM 5L | 0.446 |
LM 6L | 0.402 |
LM 8L | 0.302 |
LM 10L | 0.236 |
LM 12L | 0.226 |
LM 13L | 0.214 |
LM 16L | 0.192 |
LM 20L | 0.164 |
LM 25L | 0.12 |
LM 30L | 0.106 |
LM 35L | 0.1 |
LM 40L | 0.086 |
LM 50L | 0.068 |
LM 60L | 0.062 |
Note) Equivalent factors for the following models are the same as for model LM-L: Models LMF-L, LMK-L, LMH-L, LMIF-L, LMIK-L, LMIH-L, LMCF-L, LMCK-L, and LMCH-L.
Table6 Equivalent Factors of Model LME
Model No. | Equivalent factor: K | |
---|---|---|
Single nut | Double blocks | |
LME 5 | 0.669 | 0.123 |
LME 8 | 0.514 | 0.116 |
LME 12 | 0.389 | 0.09 |
LME 16 | 0.343 | 0.081 |
LME 20 | 0.291 | 0.063 |
LME 25 | 0.209 | 0.052 |
LME 30 | 0.167 | 0.045 |
LME 40 | 0.127 | 0.039 |
LME 50 | 0.105 | 0.031 |
LME 60 | 0.093 | 0.024 |
LME 80 | 0.077 | 0.018 |
Precautions To Be Taken if an Eccentric Load Is Applied
Since Linear Bushing is not suitable for application of an eccentric load, we recommend using Guide Ball Bushing or Ball Spline.