THK CHUO THK CHUO

Application Examples

  • Adjusting CCD camera position

    Adjusting CCD camera position
  • Adjusting the camera position for glass substrate or film inspection machines

    Adjusting the camera position for glass substrate or film inspection machines
  • Adjusting the focus or position of microscope samples

    Adjusting the focus or position of microscope samples
  • Adjusting prober position

    Adjusting prober position
  • Positioning laser displacement meters

    Positioning laser displacement meters
  • Positioning laser displacement meters

    Positioning laser displacement meters
  • Adjusting camera AF positions

    Positioning laser displacement meters
  • Positioning dispensers

    Positioning laser displacement meters
  • Adjusting laser focal points

    Positioning laser displacement meters

Fix Stages

Fix Stage features

  1. Example
    1

    After adjusting the position, the stage ends up moving when the clamp is used.

  2. Example
    2

    The stage ends up moving because of forgetting to use the clamp.

  3. Example
    3

    The stage ends up moving because the clamp comes loose.

The Fix Stage is the solution!

After adjusting the position,the stage doesn’t move even though it doesn’t have a clamp!

  • Once the stage has been moved and its position has been adjusted,it can immediately be fixed in place, and there is no need to use a clamp.
  • Thanks to a uniquely developed special mechanism, the stage doesn't move after the position has been adjusted.
After the position has been adjusted, no movement can be seen on the indicator scale even when the face of the stage is grabbed and forcefully shaken.

What does it mean to not move after position adjustment?

  • Fix stages use a hex wrench for movement.
  • The stage hardly moves even when the stage surface is directly manipulated.It will not move even when it is not clamped.

What's "Fix stage"

Reading the Model Configuration*Scroll to confirm.
TTHK CHUO LStage type STravel direction - TStage type 40stage surface 52Design symbol FXFix stage
  L…Linear S…Single   T…Thin type 25…□25    
R…Rotary D…Double P…permeation type 40…□40
T…Tilt V…Z lift No Symbol…Normal type 60…□60
51…
Select Linear type
Select Rotary type
Select Permeation type
Select Goniometer type

Center of rotation 60mm

52…
Select Thin type
Select Goniometer type

Center of rotation 40mm

Line Up

Manual Stages

Features
  • Selecting a manual stage is easy because the stage surface dimensions, travel amount, travel accuracy, etc., are made clear.
  • The stage surface mounting screw holes and base surface mounting holes are compatible, enabling them to be combined to suit customer specifications.
  • Almost all stages are equipped with a clamping mechanism as standard.

High-Grade Aluminum Stages

High-Grade Stages (Stainless Steel)

Thin VB Stages

Slim Stages, Cross Roller Stages

Others